Electric Steam Boiler

Size Range:
90 - 3,000 kW

Fuel Options:
Electric

Key Features:

  • Zero Scope-1 Emissions
  • High Steam Quality
  • Intuitive Touchscreen Control

Product Overview

Fulton’s FBZ is designed to meet the demands of sustainable energy while providing unparalleled efficiency. By eliminating the use of fossil fuels and combustion processes, this boiler offers a clean and green alternative for various industrial and commercial applications.

90-1300 kW Brochure 1500-3000 kW Brochure

  • ASME
  • ETL

The New Standard for Electric Boilers

FBZ boilers are engineered and built with Fulton’s renowned rugged durability, designed to surpass the competition right out of the box. While many competing electric boilers offer a 100kA SCCR rating or BACnet capability as optional features, the FBZ comes equipped with these and many more features and capabilities as standard.

*With appropriate fused disconnects installed upstream of unit

Rugged Design for Longer Life

The Fulton FBZ comes fully packaged and factory tested. The boiler features a rugged design with a fully insulated pressure vessel for minimal jacket losses. A carefully calculated heat-to-water ratio achieves operating pressures quickly and with nearly 100% efficiency.

  • Advanced Controls
    Touchscreen controls provide access to element staging data and full BMS integration.
  • High Quality Steam
    Large water volume and tall steam space combine to provide high quality dry steam over a wide range of operating conditions.
  • Durable & Long Lasting
    Thick walled pressure vessel exceeds ASME minimum requirements.
  • Ease of Use and Maintenance
    User friendly control interface and horizontal element bundles are easily accessibly.

Advanced Intuitive Touchscreen

  • 5.7” Color Touchscreen
  • Dedicated BMS Modbus
    – Other Integration Options Available
  • Standard I/O
    – Dedicated Outputs for Element Staging
    – Individual Input Monitoring for Safety Devices with Alarm Annunciation

Specifications & Dimensions


Print

Model
FBZ-0090 FBZ-0150 FBZ-0210 FBZ-0270 FBZ-0400 FBZ-0500 FBZ-0600 FBZ-0700 FBZ-0800 FBZ-1000 FBZ-1300 FBZ-1500 FBZ-2000 FBZ-2500 FBZ-3000
Specifications
Unit Size (kW) 90 150 210 270 400 500 600 700 800 1,000 1,300 1,500 2,000 2,500 3,000
Steam Output (LB/HR) 315 525 735 945 1,400 1,750 2,100 2,450 2,800 3,500 4,550 5,250 7,000 8,750 10,500
Water Content (GAL) 93 93 93 93 335 335 395 395 395 628 628 1,026 1,026 1,320 1,320
Dimensions
Height w/o Trim (IN) 75.875 75.875 75.875 75.875 83.75 83.75 97.5 97.5 97.5 97.75 97.75 91.25 91.25 91.25 91.25
Width (IN) 56.75 56.75 56.75 56.75 76.625 76.625 74.5 74.5 74.5 91.75 91.75 172.75 172.75 204.75 204.75
Depth (IN) 43.75 43.75 43.75 43.75 65.75 65.75 65.625 65.625 65.625 84.5 84.5 92.1875 92.1875 92.1875 92.1875
Weights
Shipping Weight (LBS) 1,500 1,500 1,500 1,500 4,300 4,300 4,500 4,500 4,500 8,580 8,580 11,790 11,790 13,650 14,550
Operating Weight (LBS) 2,125 2,125 2,125 2,125 6,800 6,800 7,640 7,640 7,640 13,500 13,500 18,020 18,020 20,195 22,680
Clearances
Element Pull 36 36 36 36 47 47 46 46 46 42.375 42.375 53 53 53 53
Electrical
208/60/3 (AMPS) 255 421 588 754 NA NA NA NA NA NA NA NA NA NA NA
240/60/3 (AMPS) 220 364 508 653 NA NA NA NA NA NA NA NA NA NA NA
480/60/3 (AMPS) 110 182 254 326 483 603 723 844 964 1,204 1,565 1,814 2,418 3,023 3,627
600/60/3 (AMPS) 88 146 203 261 386 482 579 675 771 964 1,252 1,451 1,935 2,418 2,902

FBZ Documents


result(s)
PDF
Brochures
01/26/2021
1.96 M
PDF
Brochures
08/11/2022
4.36 M
PDF
Brochures
07/11/2023
4.74 M
PDF
Brochures
06/26/2024
1.27 M
PDF
Brochures
08/30/2024
3.04 M
PDF
Brochures
04/12/2024
3.3 M
PDF
Brochures
02/25/2021
3.51 M

Find Your Local Representative

Fulton products are available for purchase through a worldwide network of authorized representatives. These representatives are highly qualified to assist you in the selection of Fulton equipment to best meet your application needs. To find your local Fulton representative, please follow the steps below.


To find a sales rep in your area, please complete the form.